GAMMA-SCOUT® Rechargeable

490,00 

The Gamma-Scout Rechargeable offers all features of the “alert” model. It is equipped with a rechargeable battery, which can be charged via USB port or power supply (included in delivery). This model has been developed for customers, who work with high radiation and need a powerful device.

SKU: RECHARGEABLE Category:

Description

GammaScout Standard

Rechargeable

Power supply, charged via USB (power supply unit or PC).

GammaScout Standard

Threshold for Dose Rate

This model features an acoustic alert when radiation level exceeds a user programmed threshold.

GammaScout Standard

Ticker

The user can set an acoustic ticker which activates with each gamma pulse detected.

 

Included features by default:

 

GammaScout Standard

Easy Reading

In measuring mode, the display shows the current radiation measurement reading every 2 sec. The display also temporarily shows the average H of the last day (24h, 12 am to 12 am).

GammaScout Standard

Energy-Saving Constant Operation

The GAMMA-SCOUT® monitors radiation day and night and logs data for later download. The “RECHARGEABLE” model works with a rechargeable battery. When the GAMMA-SCOUT® is connected to a PC, the deviceis powered via the USB port. This protects and charges the battery.

GammaScout Standard

Measures α-rays

Thanks to its LND sensor, Gamma-Scout measures α-rays in addition to γ- and β-rays.

GammaScout Standard

Large Scale

GAMMA-SCOUT® is calibrated to measure across a wide scale (0.1 up to 1,000 μSv/h)..

GammaScout Standard

Tested Calibration

Each GAMMA-SCOUT® radiation meter is subjected to a final test. This test is supervised by the Institute of Radiation Protection; a state university for applied technology. The tested device must be within a confidence interval of 5 % against a master, which in turn, is adjusted to a gauged reference Cs 137 emitter and the ODL.

GammaScout Standard

Dose Rate and Dose

GAMMA-SCOUT® can be used as a dose meter (cumulative radiation).

GammaScout Standard

Data Storage

GAMMA-SCOUT® stores all registered pulses in its internal memory and keeps them ready for you to use when desired. 32,000 readings: For constant monitoring, storage of environmental data is set at an interval of one value all 2 hours, which equates to 7 years of memory capacity. The user can set smaller intervals, which fills the memory capacity sooner.

GammaScout Standard

Data Read-Out via Microsoft WINDOWS

The measured values can be read on Microsoft Windows (WIN 7 up to WIN 10).

GammaScout Standard

Data Read-Out via MAC OS X

The measured values can be read on MAC OS X.

GammaScout Standard

Flexible Display of Data

The dose rate may be displayed in Sievert or Rem.

GammaScout Standard

Allowed on flights

GAMMA-SCOUT® may be carried on board of airplanes.

GammaScout Standard

Certification

GAMMA-SCOUT® meets also the American “FCC 15 Standard”.

GammaScout Standard

Source isotope not equal to CS 137

The conversion of pulses per time into dose rate starts from the Cs 137. In the case that other isotopes are present, you can directly display the pulses per time and convert them to their own tables.